Recirculating chillers can be ordered from Lytron or from one of our distributors.
Detailed below are Lytron's eight chiller models, their available electrical configurations, controller options, and additional options and accessories. To quickly and easily generate a part number or a quote, please use our Cooling Systems Selector Tool. To order directly from Lytron, please call +1-781-933-7300. Kodiak chillers can also be ordered from one of our international distributors.
| First Select Your Chiller Model Number |
| |
|
RC006 |
RC009 |
RC011 |
RC022 |
RC030 |
RC045 |
RC095 |
RC115 |
| Cooling capacity1 |
W kBTU/Hr |
825 2.8 |
1050 3.6 |
1650 5.6 |
2400 8.2 |
3450 11.8 |
5900 20.1 |
9600 32.7 |
11000 37.5 |
| Compressor capacity |
HP |
1⁄4 |
1⁄3 |
1⁄2 |
3⁄4 |
1 |
1 1⁄2 |
3 1/2 |
| Temperature stability2 |
|
± 0.1°C at 20°C ambient and 20°C setpoint |
| Fluid connections |
|
1⁄2˝ FNPT |
3/4˝ FNPT |
| Reservoir capacity |
|
1 gal / 4 liters |
2 gal / 8 liters |
6 gal / 23 liters |
1.75 gal/6.5 liters |
| Coolant temperature range |
|
40°F to 95°F / 5°C to 35°C |
39°F-95°F / 4°C-35°C |
| Ambient temperature range |
|
50°F to 95°F / 10°C to 35°C |
41°F-95°F / 5°C-35°C |
| Dimensions (W x D x H) |
inches mm |
12.5 x 19.0 x 22.0 318 x 483 x 559 |
14.8 x 24.5 x 26.5 376 x 623 x 673 |
21.4 x 27.8 x 31.9 543 x 705 x 810 |
32.0 x 43.0 x 45.0 813 x 1092 x 1143 |
| Weight |
dry lbs (kg) |
97 (44) |
100 (45) |
122 (55) |
166 (75) |
260 (118) |
270 (122) |
517 (235) |
| Next, Pick A Chiller Electrical Configuration |
| Electrical configurations and full load amperage3 |
G03: 115V 60Hz 1ph |
Amps |
9.9 |
12.2 |
14.3 |
n/a |
n/a |
n/a |
|
|
H03: 230V 50Hz 1ph |
Amps |
4.5 |
5.3 |
6.3 |
9.5 |
13.7 |
17.2 |
|
|
J03: 208/230V 60Hz 1ph |
Amps |
n/a |
5.8 |
7.4 |
10.0 |
14.5 |
19.6 |
|
|
M01: 200-220V 50Hz 3ph 208-230V 60Hz 3ph |
Amps |
|
|
|
|
|
|
22.2 |
22.2 |
R01: 460V 60Hz 3ph |
Amps |
|
|
|
|
|
|
11.0 |
11.0 |
T01: 380V, 50 Hz, 3ph |
Amps |
|
|
|
|
|
|
11.0 |
11.0 |
| Now, Select A Chiller Pump |
| Pump options (refer to selecting a pump and system pump graphs) |
| BB: PDP4, Brass, 1.3 gpm / 4.9 lpm |
x |
x |
x |
x |
|
|
|
|
| BC: PDP4, Brass, 1.8 gpm / 6.8 lpm |
o |
o |
o |
o |
|
|
|
|
| BE: PDP4, Brass, 2.3 gpm / 8.7 lpm |
o |
o |
o |
o |
|
|
|
|
| BG: PDP4, Brass, 4.3 gpm / 16.3 lpm |
|
|
o |
o |
x |
x |
|
|
| CB: PDP4,5, Stainless Steel, 1.3 gpm / 4.9 lpm |
o |
o |
o |
o |
|
|
|
|
| CC: PDP4,5, Stainless Steel, 1.8 gpm / 6.8 lpm |
o |
o |
o |
o |
|
|
|
|
| CE: PDP4,5, Stainless Steel, 2.3 gpm / 8.7 lpm |
o |
o |
o |
o |
|
|
|
|
| CG: PDP4,5, Stainless Steel, 4.3 gpm / 16.3 lpm |
|
|
o |
o |
o |
o |
|
|
| AA: Centrifugal, 1⁄20 HP6 |
o |
o |
|
|
|
|
|
|
| DA: Centrifugal, 1⁄4 HP6 |
|
|
o |
o |
o |
o |
|
|
| DF: Centrifugal, 1.5 HP |
|
|
|
|
|
|
x |
x |
| DD: Centrifugal, 1⁄2 HP6 |
|
|
o |
o |
o |
o |
|
|
| EB: Turbine, 1⁄2 HP6 |
|
|
o |
o |
o |
o |
|
|
| EC: Turbine, 1⁄6 HP6 |
o |
o |
o |
o |
|
|
|
|
| ED: Turbine, Bronze, 1.5 HP |
|
|
|
|
|
|
o |
o |
| FB: Turbine, Stainless Steel, 1⁄2 HP6 |
|
|
o |
o |
o |
o |
|
|
| FD: Turbine, Stainless Steel, 1.5 HP |
|
|
|
|
|
|
o |
o |
| Select Your Chiller Controller |
| Controller options |
|
RC006 |
RC009 |
RC011 |
RC022 |
RC030 |
RC045 |
RC095 |
RC115 |
| Package 17: Digital temperature display, calibration offset, low flow shut-off, auto-restart, °C/°F toggle. |
o |
o |
o |
o |
o |
o |
|
|
| Package 2: Package 1 plus digital pressure sensing, low level, low/high temperature, pressure display, fault shut-off (toggle on/off), relay contacts, audible alarm and alarm mute. |
x |
x |
x |
x |
x |
x |
|
|
| Package 3: Package 2 plus RS232. |
o |
o |
o |
o |
o |
o |
|
|
| Package 4: Digital temperature and pressure display, low level, low/high temp, low/high refrigerant pressure visual alarms, low coolant flow and low refrigerant pressure shut off, auto-restart, and °C/°F toggle. |
|
|
|
|
|
|
x |
x |
| Package 5: Same as package 4 with 25 pin D connector with DC signal for low flow, low level, low/high temperature alarms. |
|
|
|
|
|
|
o |
o |
| Package 6: Same as package 4 with 9 pin D connector with RS-232 communication. |
|
|
|
|
|
|
o |
o |
| Package 7: Same as package 5 with RS-485 communication. |
|
|
|
|
|
|
o |
o |
| Package 8: Same as package 5 with 4-20mA remote set point and retransmission. |
|
|
|
|
|
|
o |
o |
| Package 9: Same as package 5 with 0-10VDC remote set point and retransmission. |
|
|
|
|
|
|
o |
o |
| Package A: Same as package 4 plus RJ45 connector with Ethernet communication. |
|
|
|
|
|
|
o |
o |
| Add Any Additional Chiller Options |
| Available options (full description of these options can be found below) |
|
RC006 |
RC009 |
RC011 |
RC022 |
RC030 |
RC045 |
RC095 |
RC115 |
| External flow valve |
o |
o |
o |
o |
o |
o |
o |
o |
| External pressure relief valve |
o |
o |
o |
o |
o |
o |
o |
o |
| Anti-siphon system |
o |
o |
o |
o |
o |
o |
o |
o |
| Air filter |
o |
o |
o |
o |
o |
o |
x |
x |
| 5 micron coolant filter8 9 |
o |
o |
o |
o |
o |
o |
o |
o |
| Heater10 |
|
|
o |
o |
o |
o |
|
|
| Internal insulation package |
o |
o |
o |
o |
o |
o |
o |
o |
| Low temperature operation11 |
|
o |
o |
o |
o |
o |
o |
o |
| Water-cooled condenser |
|
|
o |
o |
o |
o |
o |
o |
| 0.1°C set point |
o |
o |
o |
o |
o |
o |
|
|
| Deionization package8,12 |
o |
o |
o |
o |
o |
o |
o |
o |
| High purity plumbing |
o |
o |
o |
o |
o |
o |
o |
o |
| PAO compatibility |
|
|
o10 |
o |
o |
o |
|
|
| Remote start13 |
o |
o |
o |
o |
o |
o |
o |
o |
| S2 and F47 compliance |
|
|
|
|
|
|
o |
o |
| To Arrive At A Part Number |
RC011 G03 BB 2 M__ = RC011 chiller with G03 (115V, 60 Hz, 1ph) electrical configuration, a BB pump, and controller package 2 Customization options (A 4 digit option code will be assigned at time of order, based on selected options. Leave blank if no additional options selected) x = standard o = available option |
1At 20°C setpoint, 20°C ambient, 60Hz input supply 2Assumes stable load 3With standard pump 4PDP = Positive Displacement Pump 5Only available with high purity plumbing 6Actual flow rate depends on system pressure drop. 75 piece min order 8Not available with AA and DA pump 9For RC095 and RC115, ships lose to allow protection of the chiller or customer's equipment 10Not available in G03 electrical configuration 11Requires internal insulation package 12Recommended when selecting high purity option. 13Included in Controller Packages 5-9 and A |
Kodiak Chiller Options
| Option |
Benefit |
| Chiller Protection Options |
| External flow valve: HIGHLY RECOMMENDED. A manually adjustable globe valve installed on the back of the chiller in parallel with the chiller coolant supply/return. |
Allows the operator to control the flow rate to the application. As the external flow valve is opened, more of the flow bypasses the application. |
| External pressure relief valve: A manually adjustable pressure relief valve (50 to 100 psi or 0 to 50 psi) installed on the back of the chiller in parallel with the chiller coolant supply/return. |
Allows the chiller to continue to run and maintain temperature if the flow to the application is interrupted. When flow to the application is stopped, the pressure relief valve opens and bypasses flow to the chiller’s return. It can also be used to prevent the chiller supply from exceeding a predetermined pressure setting. |
| Anti-siphon system: Check and solenoid valves installed internal to the chiller on the supply and return lines, respectively. |
Allows the chiller to be installed at an elevation below the application. Prevents backflow and subsequent overflowing of the chiller’s vented tank (if not installed, fitting leaks in the application can allow air to displace the coolant, resulting in backflow to the tank). |
| Air filter: Internally mounted on the air inlet to the condenser coil. |
Filters incoming air to the chiller’s condensing coil, preventing dust build up which can lead to decreased performance. The easy-access filter is simple to replace, reducing the need to clean the condensing coil and refrigeration components. |
| 5 micron coolant filter: Externally mounted on the supply from the chiller. |
Filters process coolant being supplied to the application, protecting equipment from blockage or damage due to particulate buildup and extending pump life. |
| Special Applications Options |
| Heater: Submerged 2,000 Watt electric resistance heater with built-in over temperature shut-off (non-adjustable). |
Allows chiller to reach elevated set points faster (useful for applications in cold start-up situations or where the coolant set point is frequently cycled). This feature does not extend the coolant temperature range of the chiller. |
| Internal insulation package: Insulated tank, pump head, and coolant lines. |
Eliminates condensation forming on the components in contact with the fluid when operating chiller at set points below the ambient dew point. |
| Low temperature operation: Chiller coolant temperature range is –5°C to +25°C. (Note: internal insulation package must also be selected). |
Optimizes performance for low temperature operation and provides additional low temperature cooling capacity compared to standard chillers. Contact Lytron’s applications engineering department for performance graphs. |
| Water-cooled condenser: Refrigerant is condensed using water (rather than ambient air) via a liquid-to-liquid heat exchanger. |
Heat that would normally be rejected to the ambient environment is transferred to an external liquid coolant source, avoiding room warming and possible air conditioning overload. Also, water-cooled chillers are quieter because there is no condenser fan. Contact Lytron for required facility liquid coolant flow rate and temperature requirements. |
| 0.1°C set point: Allows 0.1°C increments of the set point and display temperatures. |
Allows more precise control of the coolant delivery temperature. Available in °C only. |
| Fluid Compatibility Options |
| Deionization Package: Externally mounted DI cartridge (no indicator light) on the return to the chiller. |
Filters ions from coolant to maintain a fluid resistivity level between 1 and 3 megohm/cm by partial flow through the resin bed. This feature does not include a resistivity indicator light. High purity plumbing is recommended with the DI water cartridge. |
| High purity plumbing: Includes nickel-brazed evaporator and nickel-plated or nylon fittings compatible with DI water. Not compatible with brass pumps. |
All wetted materials are fully compatible with DI water to prevent component corrosion. |
| PAO compatibility: Includes pump, fittings, hose, and oil filter compatible with polyalphaolefin (PAO). Anti-siphon system and internal insulation packages are included in this option. |
All wetted materials are fully compatible with PAO. Contact Lytron for PAO performance curves. |
| Chiller Convenience Options |
| Remote start: Chiller power can be cycled through a computer or relay. |
Allows an external circuit to control the chiller on/off function via dry contacts on the rear of the chiller. |
| Please refer to the chiller technical manual for further discussion of these features. | Kodiak Chiller Controllers
| Controller Option |
Functionality |
Controller Package |
| Digital temperature display |
Easy-to-read display in either °C or °F. |
All |
| Calibration offset |
Allows temperature display to be offset to represent the temperature at a different point within the cooling circuit. |
1,2,3 |
| Low flow shut-off fault |
Alerts user to a lack of coolant flow and shuts down the chiller to prevent the refrigeration system from freezing. |
All |
| Auto-restart |
Automatically returns chiller to its operating status prior to interruption of power, e.g., if the chiller was on, it will turn back on when power is restored. |
All |
| °C/°F toggle |
Enables temperature display to be viewed in °C or °F. |
All |
| Audible alarm |
Audible warning of all fault conditions. |
1,2,3 |
| Alarm mute |
Silences audible alarm until the alarm is cleared or the chiller turned off. |
1,2,3 |
| Digital pressure sensing |
Displays pump output pressure (psig or bar) and allows it to be transmitted through RS232. |
2 - 9 Plus A |
| Low level fault |
Alerts user that the coolant level in the reservoir is at a critically low level (approaching the level of the pump’s suction line). Switches chiller off if ‘fault shut-off’ is on. |
2,3 |
| Low/high temperature fault |
Alerts user that the coolant temperature is outside of the user’s defined set-point limits. Switches chiller off if ‘fault shut-off’ is on. |
2 - 9 Plus A |
| Low/High refrigerant pressure visual alarms |
Protects the compressor from high pressure due to excessive heat buildup in the refrigerant and also from a low refrigerant suction pressure condition. |
4 - 9 Plus A |
| Remote set point and retransmission |
Provides for either a 4-20 mA or 0-10 VDC analog signal to change the coolant set point based upon the process cooling requirements. |
8 and 9 |
Fault shut-off (toggle on/off) |
Allows chiller to be programmed to shut down on fault (on) or continue to run during fault conditions (off). The chiller will always shut down on the low flow shut-off alarm. |
2,3 |
Single Relay contacts (normally open or normally closed) |
Fault conditions of the chiller can be monitored by applying a low voltage power signal across dry contacts at the rear of the chiller. (Power loss to the chiller is not a fault condition.) * Mating connector—AMP part number 350715-1 and 350547-1 |
2,3 |
| Multiple Relay Contacts |
Via the 25 pin connector, provides multiple dry contacts for customer signals for coolant over temperature, reservoir low level condition and pump low flow condition. |
5 - 9 |
| RS232 communications and /or RS-485 communications |
Allows complete control of all the chiller’s controller features (changing/monitoring coolant set point, monitoring pressure, and fault alarms, etc.) from a remote computer for monitoring, control, and data logging. |
3,6 |
| Ethernet communication |
Provides chiller control/monitoring via Ethernet communications |
A | Package 2 is the standard package for RC006 to RC045 Kodiaks. Kodiak Chiller Accessories
| Item |
Description |
Part Number |
| Water Filter Kit for RC006-RC045: |
1⁄2˝ fluid connections. Contains 5 micron filter, filter housing, mounting bracket, 1´ hosing, base clamps, and assembly instructions. |
200-0441
|
| Water Filter Kit for RC095-RC115: |
Process fluid filtration kit contains a 5 micron particle filter. ¾” Nylon® hose barb fittings included |
324-70004-000 |
| Plumbing package: |
1⁄2˝ fluid connections. Contains 50’ Nylabraid™ hose, 50’ Armorflex™ insulation, male NPT to barb fittings, hose clamps. |
200-0193 |
| External pressure relief valve kit:(50 - 100 psi) |
1⁄2˝ fluid connections. For applications requiring reduced pressure. This kit contains a pressure relief valve, 2 tees, hose clamps, and plumbing instructions. Assembly required. |
200-0196 |
External pressure relief valve kit: (0 - 50 psi) |
1⁄2˝ fluid connections. For applications requiring reduced pressure. This kit contains a pressure relief valve, 2 tees, hose clamps, and plumbing instructions. Assembly required. |
205-0080 |
| External manually adjustable flow valve: |
1⁄2˝ fluid connections. For applications requiring flow control. Kit contains flow valve, 2 tees, hose clamps and plumbing instructions. Assembly required. |
200-0298 |
| 115V power cord: |
25’ |
250-0092 |
| 230V power cord: |
25’ |
250-0093 |
| RS232 cable: |
10’ |
250-0091 |
| Dry contact cable: |
10’ |
250-0159 |
| 5 micron replacement coolant filters* |
RC006-RC045: 330-0022 RC095-RC115: 013-25213-000 |
| Air filters* |
RC006/RC009: 330-1541 RC011/RC022: 330-0977 RC030/RC045: 330-0683 RC095/RC115: 013-50018-002 |
| Deionization cartridge |
RC006-RC045: 430-0330 RC095-RC115: 013-50027-000 | *10 piece minimum Please use our Cooling Systems Selector Tool to generate a recirculating chiller part number or quote.
Get More Information
Complete our short form to request a quote or catalog or ask an engineer a technical question.
|
 |
 |
 |
|